STALIF C-Ti™
With Ti ACTIVE™ Titanium-Enhanced PEEK Technology
Based on the successful STALIF C® device, STALIF C-Ti™ incorporates a novel, titanium-surfaced PEEK Integrated Interbody™ design that is raising the Gold Standard of cervical interbody.
* The device system is designed for use with autograft bone and/or allogeneic bone graft composed of cancellous and/or corticocancellous bone graft, to facilitate fusion. Multilevel indicates for 1-2 contiguous levels.

Optimized Surface Technology.1
Raising the Gold Standard with Ti ACTIVE™
The Ti-ACTIVE™ surface provides a three-dimensional texturized surface that is microporous with hydrophilic properties, to facilitate human mesenchymal stem cell (hMSC) attachment and proliferation as demonstrated by pre-clinical testing performed on representative PEEK coupons with Ti-ACTIVE surface.2
During manufacturing, commercially pure titanium (CP Ti) is applied to the PEEK cage by a plasma spray to create our Ti-ACTIVE devices. The unique CP Ti surface system utilizes a robotic applicator, enabling the creation of a high-quality, reproducible titanium surface.3 Ti-ACTIVE was tested for mechanical integrity and the results exceeded the FDA requirements for shear and tensile strength for metallic spray surfaces.4
1 Lebl DR. Mechanical performance of cervical TDRs in vivo. Spine (Phila, PA 1976) 2012 Dec 15; 37(26): 2151-60.
2 Yoon BJV, Cammisa FP, Abjornson C. Polishing methods less a factor in cell adhesion than surface characteristics of titanium plasma spray surfaces on PEEK. Paper presented at Lumbar Spine Research Society Meeting, 2015 April, Chicago, IL.
3 Centinel Spine Report VAL-2013-043.
4 Centinel Spine Report CD12-03-07-020.

Texturized Titanium Surface1
SEM image (2,000x magnification) of the surface of a standard PEEK implant (left) and a titanium-applied PEEK implant (right). Unlike standard PEEK, the PEEK with titanium surface provides a 3-D microporous environment conducive to cell attachment and cell migration, seen by cytoplasmic expansions of the cultured cells, as highlighted in purple.

Ti-ACTIVE™ PEEK Surface of STALIF C-Ti™
Cell Proliferation
SEM image (2,000x magnification) showing cellular interaction allowing human mesenchymal stem cells (hMSCs) to communicate when receptors and markers bind on a Ti-ACTIVE™ surface. Cell to cell interactions are vital in the promotion of cell adhesion and later the function of the cell to differentiate and proliferate, as highlighted in yellow. Ti-ACTIVE™ offers an optimized surface topography enabling cellular migration, cellular interaction, and cellular attachment to the surface as observed on representative STALIF® coupons with Ti-ACTIVE™ surface.2
Integrally PEEK.
Blending the Benefits of Titanium and PEEK
By preserving its PEEK roots, STALIF C-Ti™ exhibits a modulus of elasticity similar to bone. In doing so, the device presents a reduced risk of subsidence relative to all-titanium cages.5 Additionally, STALIF C-Ti™ continues to maintain the radiolucent advantage of PEEK.
5Ashman RB, et al. A continuous wave technique for the measurement of the elastic properties of cortical bone. J Biomech, 1984; 17(5):349-61.
6Chen Y, Wang X, et al. Comparison of titanium and polyetheretherketone (PEEK) cages in the surgical treatment of multilevel cervical spondylotic myelopathy: A prospective, randomized, control study with over 7-year follow-up. Eur Spine J, 2013; http://dx.doi.org/10.1007/s00586-013-2772-y.
7Centinel Spine Report VAL-2014-009.

Radiolucent Advantage
The STALIF C-Ti™ device maintains the radiolucent advantage of PEEK, making it easier to assess post-operative development of fusion mass during follow-up.7 The Ti-ACTIVE™ surface allows for radiographic visualization of the graft-endplate contact. Images show radiographs of STALIF C-Ti™ in Anterior/Posterior view (left) and Lateral view (right).

Osteo-Similar Modulus
PEEK is less rigid than titanium. PEEK's elastic modulus is closer to that of cortical bone (see chart above).4 Compared to all-titanium cages, PEEK cages have been shown to be six times less likely to experience subsidence.6
Inherently STALIF®
Standing on the Solid STALIF® Platform
STALIF C-Ti™ is built upon the simple, elegant design and proven success of the STALIF® foundation.

No Profile®; No Supplemental Fixation
STALIF C's integrated cage and screw system is cleared for use without supplemental fixation, while the "No-Profile" design allows it to nest fully within the confines of the vertebral body—leaving the anatomy unchanged external to the interbody.

The Lag Effect
Compressive lag fixation ensures biomechanical stability and provides secure graft-endplate contact. Lag screws reduce the vertebral bodies onto the cage creating graft / endplate surface compression to provide the best opportunity for fusion.

Biomechanical Equivalence
The STALIF C-Ti device is engineered to achieve equivalent biomechanical performance to anterior plate & cage technologies.8
8Stein MI, Nayak AN, Gaskins RB, Cabezas AF, Santoni BG, Castellvi AE; Biomechanics of an Integrated Interbody device versus ACDF anterior locking plate in a single-level cervical spine fusion construct. Spine J., January 2014; 14(1):128-136.

Anti Back-Out® Screws
STALIF C® screws provide an added layer of security with an Anti Back-Out® (ABO®) titanium split-ring which first compresses and then deploys during insertion.
Have questions?
ContactYou’ll find us knowledgeable, helpful, and almost always available. We remember what it was like to be a customer, too.